Assignment: Outcomes on preventing (HAIs)

Assignment: Outcomes on preventing (HAIs)

Assignment: Outcomes on preventing (HAIs)

This presentation builds upon and utilizes information gathered and reported in the first two assignments (RUA). Suggestions for implementation of outcomes on preventing (HAIs) should clearly and delineate the following.

A) Measurable outcome 1 slide

B) Feasibility issues 1 slide

 

Strategies for the implementation of measurable outcomes

2 slides with speaker notes including in-text citations

1 Reference slide of both articles used.

Articles to be used are attached

ORDER CUSTOM, PLAGIARISM-FREE PAPER

Background: Alcohol sanitizers have not been demonstrated to reduce hospital-acquired infections over handwashing alone in controlled, well- designed clinical studies. A major reason for this may be the failure of traditional alcohol sanitizers to provide any residual, or persistent, activity. Any lapse in hand hygiene protocol then leaves patients and staff open to transmitting pathogens. The purpose of the study was to determine whether a persistent sanitizer would reduce hospital-acquired infection in a hospital setting as compared to handwashing alone. Materials and Methods: A controlled, crossover study was conducted in three wards of a hospital over the course of three months. Two months were assigned as control periods, while the third month the test product was added. More than 6,000 patient-days were evaluated. Hospital staff were given a questionnaire to determine overall satisfaction with the product. The product used was a persistent, alcohol-based hand sanitizer (Zylast Antiseptic, 76% v/v ethyl alcohol) Results: Control data showed that the hospital had a standard hospital-acquired infection rate of 23.1% across the three wards. No hospital-acquired infections were reported during use of the Antiseptic. The product was well tolerated by the staff and improved skin condition. Conclusion: The Antiseptic was demonstrated to significantly (p < 0.0005) reduce the hospital-acquired infection rate as compared to handwashing alone and is well-tolerated in a healthcare setting. The novel, persistent product has the ability to significantly reduce hospital-acquired infection and improve patient care in medical facilities.

Key words: Hospital-acquired infection, benzethonium chloride, antiseptic, Zylast, nosocomial infection, persistent, hand hygiene

Introduction

Hospital-acquired infections (HAIs) are a serious danger to patients, particularly as a growing percentage of these infections are resistant to antibiotics (Hawkey and Jones, 2009). Between five and ten percent of patients admitted will acquire an infection while in the hospital (Centers for Disease Control and Prevention, 2002). The increased resistance to antibiotics has made treatment costs even higher; HAIs cause nearly 100,000 deaths annually in the United States, (Centers for Disease Control and Prevention, 2002) as well as 10% of admitted patients in developing countries (World Health Organization, 2013). Assignment: Outcomes on preventing (HAIs)

Much of the spread of nosocomial infection in hospitals is linked to a lack of compliance in hand hygiene. While the United States Centers for Disease Control (CDC) recommends handwashing for 1-2 minutes, multiple studies have shown that the actual duration among heathcare workers is often less than 15 seconds (Quraishi, McGuckin and Blals, 1984). Even with the presence of alcohol-based sanitizers in convenient locations near patient rooms and in hallways, compliance with hand hygiene is only 40% (Erasmus, 2010). Skin irritation from repeated washing or the drying of the skin with traditional alcohol-based sanitizers may play a large role in the failure to comply with hand hygiene protocol among healthcare workers, as nearly 85% of healthcare workers have reported dry, cracked, or irritated skin as the result of hand hygiene products (Centers for Disease Control and Prevention, 2002).

However, improvements in compliance with hand hygiene protocols do not necessarily result in a reduction in the rate of HAIs in hospitals. In one study, compliance improved from 38% to 69% as a result of introducing a hand sanitizer in addition to handwashing alone, but the authors concluded, ‘This improvement in the hand hygiene adherence rate was not associated with detectable changes in the incidence of healthcare-associated infection’ (Rupp, 2008). Another study monitored hand hygiene and pathogen transmission, concluding there was “no correlation between the transmission rates of nosocomial pathogens…and hand hygiene compliance” (Eckmans, Schwab et. al, 2006).

A major limitation of traditional alcohol-based sanitizers is the inability to provide persistent protection against transient germs; once the product evaporates, antimicrobial activity no longer exists (Centers for Disease Control and Prevention, 2002). In other words, hands can immediately become recontaminated when they come into contact with a surface containing bacteria or viruses, leaving patients unprotected when healthcare workers do not adhere to hand hygiene protocol. The United States Food and Drug Administration states in their Tentative Final Monograph, ‘Persistence, defined as prolonged activity, is a valuable attribute that assures antimicrobial activity during the interval between washings, and is important to a safe and effective healthcare personnel handwash’ (FDA, 1994).

For these reasons, multiple clinical studies have proven that the addition of a traditional, alcohol-based hand sanitizer does not reduce infection rates in hospital settings when compared to handwashing alone (Rupp et al, 2008; Parienti et al, 2002) and may increase the risk of infection for patients by up to 33.4% (Doebbeling et al, 1992; Larsen et al, 2005). Another study in long-term care facilities showed that facilities that relied on a traditional alcohol sanitizer were six times more likely to have a disease outbreak than ones that rely on handwashing alone (Blaney et al, 2011).

The purpose of this clinical study is to examine the ability of a novel hand sanitizer with persistent antimicrobial activity against transient bacteria to reduce the rate of infection in a hospital setting. The novel antiseptic product used in this trial has demonstrated rapid, broad-spectrum kill in the FDA-specified time-kill testing, showing an average reduction of >99.999% within 15 seconds of the 25 different microorganisms tested (Czerwinski et al, 2014). The active ingredients have been shown to persistently pass the Surgical Scrub test as well as the Healthcare Personnel Handwash Test as described in the FDA Tentative Final Monograph (Shintre et al, 2006). After being applied to human skin and allowed to dry in the in-vivo Cup Scrub test, the Antiseptic destroyed more than 99.9% of a transient pathogen (E. coli) on contact at 20 minutes, 1 hour, and 6 hours after application (BioScience Laboratories, 2014). In contrast, a standard alcohol sanitizer had no effect at any of the timepoints tested. The test product

 

 

Kampiatu and Cozean Afr. J. Infect. Dis. (2015) 9(1): 6 – 9 http://dx.doi.org/10.4314/ajid.v9i1.2

7

has also been shown to be more than 100 times as effective in reducing the Norovirus surrogate on the skin than alcohol alone (Czerwinski and Cozean, 2012).

Materials and Methods Study Design

It was hypothesized that a product with rapid, broad spectrum kill that provides persistent protection and reduces irritation would reduce infection rates. The study tracked infection rates in three different wards of the hospital over 3 months. The first and third months served as controls, using the standard handwashing techniques of the hospital, while the novel antiseptic product was used in all three wards during the second month, allowing for a comparison of the rates of infection using the sanitizer versus standard handwashing techniques. This crossover design allowed each ward to serve as their own control, ensuring that differences in the wards or study populations did not affect the outcome of the study.

The control and treatment groups were displaced in time in accordance with recommendations from the Food & Drug Administration. Because of the persistent efficacy of the Antiseptic, a nurse who used the persistent product and moved to another patient or ward would still have protection and would confound the study. The only way to perform a controlled study with a persistent product was to have the patients in the control and treatment groups completely displaced in time and/or space. There was no nursing crossover between the different wards of the study. Each medical personnel entering a ward would perform one of the following tasks:

1) Wash his/her hands according to standard hand hygiene protocols as part of the control group or; 2) Apply Antiseptic per the instructions on the bottle as part of the treatment group. The instructions state, “Wet hands thoroughly with product and

allow to dry without wiping.” No additional training, education, reminders, or materials were given to the experimental group.

Facility Assignment: Outcomes on preventing (HAIs)

The hospital selected for this clinical study was Kikuyu Hospital, one of the foremost private hospitals in East Africa. Three wards were used in this trial to evaluate the Antiseptic: the Men’s Ward, the Women’s Ward, and the Eye Care Ward. The staffs of the three wards were separate, and there was minimal staff or patient interaction between the wards.

Test Product

The active ingredient in the Zylast Antiseptic (manufactured by Innovative BioDefense, Inc.) used in this trial is 76% ethanol. Persistence is provided by a synergistic combination of ingredients centered around benzethonium chloride (BZT), a compound which has been known since the 1970’s to be safe and effective against both bacteria and viruses and has a persistent effect. The efficacy is enhanced by a proprietary, patent-pending combination of ingredients that reduces irritation to the skin, enhances efficacy against gram-negative bacteria, and allows persistent efficacy against transient germs for six hours. Like alcohol, the product kills all test strains of bacteria to a 99.99% level in seconds. The manufacturer suggests a dosage amount of 0.4 ml per use, which was regulated by the dispenser.